← Back to the thermal model

External anchor · read only

Fisher House validation case

This page runs the complete, locked Fisher geometry, assemblies, ventilation inputs and transcribed PHPP climate. Nothing here is applied to the current project and none of these controls are editable.

Locked benchmark

Monthly heat-balance reconciliation

Industry-issued PHPP monthly heating-balance anchor. The engine was not adjusted to fit it. This validates the monthly method on the locked Fisher case and its transcribed assemblies. It does not validate this project's inputs, the production NIWA climate pipeline or the experimental hourly engine.

The unchanged monthly engine reproduces Fisher’s published heating demand within 1.98%. This validates the heat-balance method on this case, not every production input.
Term Fisher report ICF Designer Residual
Transmission 96.50 kWh/m² 93.92 kWh/m² -2.68%
Ventilation 24.60 kWh/m² 24.20 kWh/m² -1.60%
Solar Gains 72.30 kWh/m² 70.00 kWh/m² -3.19%
Usable Gains 79.40 kWh/m² 77.24 kWh/m² -2.72%
Heating 41.70 kWh/m² 40.88 kWh/m² -1.98%

Source: H1_REPORT_SAMPLES/Thermal Modelling Reports/240214 Fisher House H1.pdf

Production climate-pipeline check

This is a diagnostic reconciliation of the production NIWA climate path. It does not alter the locked Fisher fixture and does not calibrate the engine.

Status: divergent unanchored. The Fisher heat-balance anchor does not currently extend to the production NIWA climate and ground-temperature pipeline.
Fisher climate · Fisher geometry 40.88 kWh/m²·yr · transcribed NZ1006c climate
NIWA at Fisher site · 343 m 41.98 kWh/m²·yr · same geometry and specification
NIWA at flagship site · 420 m 45.95 kWh/m²·yr · elevation changed only
Decomposition residual +0.000 kWh/m²·yr · explicitly closed
Same-site pipeline difference +1.10 kWh/m²·yr · NIWA vs PHPP at 343 m
Elevation effect +3.97 kWh/m²·yr · 343 m to 420 m
Maximum monthly dry-bulb difference 1.28°C Agreed limit 1.0°C
Maximum ground-temperature difference 4.57°C Agreed limit 1.0°C
  • Monthly NIWA dry-bulb differs from the PHPP series by more than the agreed 1.0°C maximum.
  • Annual vertical irradiation differs by more than 5% on at least one orientation. The Hay-Davies implementation is independently checked against pvlib, so the remaining Fisher difference is a climate-dataset diagnostic rather than an untested transposition.
  • The production path uses the NIWA/MBIE EPW monthly ground series at its stated depth. It does not reproduce Fisher's separately transcribed PHPP ground-temperature series within tolerance.
Month-by-month PHPP versus production NIWA series

Solar cells show Fisher / NIWA at 343 m in kWh/m². Temperature cells show Fisher / NIWA in °C. The production ground series is currently the disclosed constant annual-mean dry-bulb proxy.

Month Dry bulb Ground North solar East solar South solar West solar
Jan 15.3 / 16.1 16.9 / 16.4 102.0 / 92.3 115.0 / 101.4 51.0 / 57.4 118.0 / 120.6
Feb 15.8 / 15.8 18.3 / 16.8 106.0 / 100.0 92.0 / 90.8 32.0 / 40.5 95.0 / 101.8
Mar 12.8 / 14.1 15.2 / 15.3 123.0 / 117.0 79.0 / 81.0 28.0 / 30.6 87.0 / 82.5
Apr 9.8 / 10.2 14.2 / 12.8 116.0 / 121.5 55.0 / 59.8 18.0 / 19.1 59.0 / 59.0
May 6.8 / 7.0 13.2 / 10.4 101.0 / 91.9 38.0 / 37.9 12.0 / 13.1 35.0 / 29.3
Jun 4.0 / 4.3 12.0 / 7.7 93.0 / 92.8 28.0 / 28.0 10.0 / 10.8 29.0 / 29.0
Jul 2.4 / 2.9 10.8 / 6.2 110.0 / 102.5 38.0 / 34.0 11.0 / 11.6 34.0 / 31.8
Aug 4.8 / 5.5 10.0 / 7.3 115.0 / 117.9 48.0 / 48.6 16.0 / 18.5 50.0 / 53.2
Sep 7.7 / 7.7 9.8 / 9.2 120.0 / 120.1 74.0 / 72.4 23.0 / 26.7 74.0 / 70.7
Oct 9.8 / 10.0 10.3 / 11.1 109.0 / 109.7 80.0 / 92.2 33.0 / 38.9 92.0 / 95.7
Nov 11.4 / 11.8 11.4 / 12.8 98.0 / 96.5 95.0 / 105.4 44.0 / 53.8 107.0 / 110.3
Dec 14.8 / 14.7 14.8 / 14.9 100.0 / 89.5 112.0 / 113.8 53.0 / 60.8 117.0 / 112.1

Production file: TMY3_NZ_QL.epw · station elevation 354 m ASL · SHA-256 6554221e4f1bb23ff253c72927ff72d8b259e73f1c2fe41739f96430c2c26853