Interactive Demo — Demonstration House · project 13188 · revision 1 · envelope explorer
See what each thermal decision changes.
Explore the same building geometry with different envelope specifications. Live results use the fast comparative model; the EnergyPlus report is the higher-fidelity hourly assessment.
Thermal envelope and test record
First, your ceiling
Confirm which spaces form the heated envelope, review the fabric takeoff, and record a measured airtightness test. This summary uses the saved project specification. These details save only when you choose Save envelope record.
Is your ceiling flat, or does the insulation follow the roof? The result is worked out from your answer. It saves only when you choose Save envelope record.
Fabric areas use outside wall faces. Floor area and enclosure volume use inside wall faces. No net air partition deduction is applied.
Envelope components
Component U-values are area-weighted where values are known. Shares use the known fabric heat-loss subtotal.
| Component | Included area | Known area | Area-weighted U-value | Known heat loss | Share of known subtotal | Coverage |
|---|
Thermal bridges and ventilation heat loss are excluded from this fabric UA subtotal.
EnergyPlus export for this conditioned-envelope model is not yet supported. Annual results require complete geometry and supported thermal boundaries.
Inputs still required
Conditioned levelsCeiling boundary
Include the levels inside the heated envelope. Leave optional measurements blank unless they are known.
Choose one answer for each heated level.
Answer this and the result appears.
Measured airtightness test
Enter the tester's Q50 airflow or their ACH50 result. This record is separate from the design airtightness target.
Advanced envelope boundaries and measurements
| Surface | Type | Boundary | Level | Orientation | Assembly | Area | U-value | R-value | Heat loss | Known share | Source | Status | Override |
|---|
Geometry notes
We've assumed a 25° pitched roof over the whole floor plan. Your heating figure will change once you design the real roof.
Quick comparison model. Use it to compare choices; the figures are indicative, not a compliance result. How reliable is this?
Comfort, ventilation, solar admission and input sensitivity affect this result.
What affects this result
Openable-window cooling is modelled before active cooling. A no-summer-ventilation sensitivity will appear here. Comfort band: 20–24°C. Percentage of occupied hours within the band is not calculated by this monthly model. Gain-sensitivity diagnostic pending.Specification changed
Same house, compared simply
Compare this design with a typical NZ code-built house using the same geometry. The statutory H1/VM1 basis is shown separately.
Annual demand
Reference details
The indicative code-built house uses the same geometry with a code-minimum envelope, assumed 5 ACH50 and no heat recovery.
The H1/VM1 reference holds geometry, airtightness, ventilation, MVHR and services equal; only insulation and glazing change to code minimum.
Temperature behaviour
Same geometry and real NIWA weather. The comparison uses the applicable code-minimum envelope, 5 ACH50, no heat recovery and lightweight construction.
Temperature behaviour only · no hourly energy or cost claim in monthly mode
Green and orange are free-running temperatures. Purple dashed shows this build with active temperature control; when the hourly annual model is selected, it corresponds to the heating, cooling and cost figures above.
Real NIWA weather with modelled indoor temperatures. Indicative and independently unvalidated; these are not measured conditions, an H1 compliance result or a guarantee of actual performance.
Capital-cost breakdown
Building geometry used
Net external areas come from the current project model. Openings are shown separately and are not double-counted in the opaque wall area.
—
Inputs and external check
Every result-driving input carries its value, source and current evidence status.
The external anchor validates the monthly method, not this building’s assumptions.
The hourly model has no external validation anchor of its own. The external anchor below validates the monthly method only.
Validated against an independent PHPP model within 2%. See the term-by-term reconciliation in full evidence mode.
Component evidence status
| Component | Status | Basis |
|---|
Input provenance register
| Input | Value | Source | Status |
|---|
External term-by-term reconciliation
| Term | Validation house | ICF Designer | Residual |
|---|