Interactive Demo — Demonstration House · project 13188 · revision 1 · envelope explorer

See what each thermal decision changes.

Explore the same building geometry with different envelope specifications. Live results use the fast comparative model; the EnergyPlus report is the higher-fidelity hourly assessment.

Loading saved result…

Thermal envelope and test record

First, your ceiling

Confirm which spaces form the heated envelope, review the fabric takeoff, and record a measured airtightness test. This summary uses the saved project specification. These details save only when you choose Save envelope record.

Is your ceiling flat, or does the insulation follow the roof? The result is worked out from your answer. It saves only when you choose Save envelope record.

Loading envelope details…
Quick comparison model. Use it to compare choices; the figures are indicative, not a compliance result. How reliable is this?
Quick comparative model Use the live result to compare orientation and specification choices. Absolute demand and the size of any benefit remain indicative.
Earlier demonstration-house cross-check On an earlier demonstration house, the live model was higher than EnergyPlus at every tested orientation. That conservative result covers that house only; it is not yet a universal claim.
EnergyPlus & compliance EnergyPlus is the preferred higher-fidelity technical assessment. It remains input-dependent; compliance is determined separately.
Annual space-conditioning demand
— kWh/m²·yr — energy used per square metre of floor, per year kWh/m²·yr
Heating — Cooling —

Comfort, ventilation, solar admission and input sensitivity affect this result.

What affects this result Openable-window cooling is modelled before active cooling. A no-summer-ventilation sensitivity will appear here. Comfort band: 20–24°C. Percentage of occupied hours within the band is not calculated by this monthly model. Gain-sensitivity diagnostic pending.
Estimated annual running cost — Estimate Using declared defaults of 40¢/kWh and a typical heat pump. SCOP (seasonal coefficient of performance) 3.5 means about 3.5 units of heat for each unit of electricity across the heating season. Complete the running-cost choices to compare this build with a typical NZ code-built house.

Same house, compared simply

Compare this design with a typical NZ code-built house using the same geometry. The statutory H1/VM1 basis is shown separately.

Annual demand

This buildDesign weather
—
NZ code-built houseSame geometry · code-minimum envelope
—
H1/VM1 referenceCompliance basis · services held equal · reference zone
—

The bar scale adjusts to the highest result shown. Use the numbers at right for absolute changes.

Reference details

The indicative code-built house uses the same geometry with a code-minimum envelope, assumed 5 ACH50 and no heat recovery.

The H1/VM1 reference holds geometry, airtightness, ventilation, MVHR and services equal; only insulation and glazing change to code minimum.

Annual energy saving — Against a typical NZ code-built house
Simple payback — Indicative; excludes finance and escalation
Capital-cost breakdown

Building geometry used

Net external areas come from the current project model. Openings are shown separately and are not double-counted in the opaque wall area.

—

Net external walls — Opaque wall area after openings
Gross glazed openings — Windows and glazed openings
External doors — Opaque external doors
Roof — Modelled external roof area
Treated floor — Conditioned floor area
Gross heat loss — Envelope, junctions and ventilation
Usable free gains — Solar and internal gains used by the calculation
Net conditioning demand — Heating plus active cooling after usable gains

Inputs and external check

Every result-driving input carries its value, source and current evidence status.

The external anchor validates the monthly method, not this building’s assumptions.

Gross-to-net amplification — Diagnostic pending
External monthly anchor — Term-by-term external reconciliation
Component evidence status
ComponentStatusBasis
Input provenance register
InputValueSourceStatus
External term-by-term reconciliation

TermValidation houseICF DesignerResidual
Open the locked validation case
Assumptions and data sources

    This is a temporary thermal scenario

    Rotating here recalculates solar exposure and thermal results so you can compare orientations.

    It does not change the project’s saved aspect. Project Settings and downloaded reports continue to use the saved orientation.